Transient Specialists INC. offer a comprehensive range of KeyTek pulsed immunity equipment for short or long-term rental.
The range includes equipment for testing to BELLCORE, UL, FCC, CCITT and other standards, not otherwise commonly available within the United Kingdom.
Further product information on this web-site can be accessed by selecting the information icon ().
Equipment is supplied directly from the USA. For further information, enquiries or datasheets, please contact us.
ESD | CEMaster | EMCPro | ECAT | Manual Surge | Telecom
| Electrostatic Discharge Simulators | |
|---|---|
| Minizap | |
| MZ-15/EC | ESD Simulator; ±15kV Air Discharge, ±8kV Contact Discharge with 150pF/330 Ohm discharge network. Complete with True-ESD air discharge tip (TPA-1), air discharge IEC ball tip (TPA-2), contact discharge tip (TPC-2A), battery charger and soft carry case. Compliant with and exceeding the requirements of IEC 1000-4-2 and ANSI C63 standards. |
| MZEC1 | ESD Simulator; ±15kV Air Discharge, ±8kV Contact Discharge with 150pF/330 Ohm discharge network. Complete with True-ESD air discharge tip (TPA-1), air discharge IEC ball tip (TPA-2), contact discharge tip (TPC-2A), True-ESD fastest risetime contact-mode tip (TPC-1), self discharge tip (TPF-1), standoff spacer (50-MZ), battery charger and soft carry case. Compliant with and exceeding the requirements of IEC 1000-4-2 and ANSI C63 standards. |
| HBM-MZ15 | Human Body Model Relay module with 100pF/1500 Ohm discharge network for Minizap according to MIL-STD 883D. |
| Series 2000 | |
| 2001 | ESD-1 Simulator; ±25kV with DN-10 150pF/330 Ohm discharge network. |
| 2002 | ESD-1 Simulator; ±25kV with DN-10 150pF/330 Ohm discharge network, CIA-20 direct current injection adapter and FT-12 H-Field simulator. |
| 2030STD | ESD-1 Simulator; ±25kV with DN-10 150pF/330 Ohm discharge network and CIA-V contact discharge adapter (as required by IEC 1000-4-2). |
| CIA-V | Contact discharge adapter according to IEC 1000-4-2. |
| DN-1 | Discharge network; 150pF/150 Ohm (for testing to older versions of IEC 801-2). |
| DN-2 | Discharge network; 100pF/1500 Ohm (for testing to NEMA Part DC33 and MIL-STD 883c). |
| DN-4 | Segmented Body Model Discharge network; 700pF/100 kOhm, 150pF/150 Ohm, 20pF/50 Ohm. |
| DN-5 | Discharge network; 60pF/10 kOhm. |
| DN-6 | Optimum basic Human Body Model Discharge network; 100pF/500 Ohm (for testing to EIA Std. PN-1361 (Draft 6, 1985)). |
| DN-7A | Discharge network; 330pF/2 kOhm. |
| RT-1850 | Adapter for use with DN-1 to increase resistance to 2 kOhm (capacitance remains 150pF). |
| EC-1 | Probe conversion cable. Enables any discharge network to be used as a light hand held probe remotely from the main ESD-1. |
| Top | |
| CEMaster | |
| CEMaster | CEMaster System comprising: CM-Base with single phase 16A AC/DC coupler and NEMA (US) outlet, front-panel keypad and display, Windows application software, RS232 Fibre-Optic interface, CM-EFT Electrical Fast Transient Bursts simulator (to IEC 1000-4-4, 2.5kV), CM-SURGE Combination wave surge simulator (to IEC 1000-4-5, 2.5kV), CM-HPWR Power frequency magnetic field simulator (to IEC 1000-4-8, 4A/m) [N.B. requires CM-HCOIL], CM-HPULSE Pulsed magnetic field simulator (to IEC 1000-4-9, 800A/m) [N.B. requires CM-HCOIL] and CM-PQF Dips and Interrupts (to IEC 1000-4-11, 100%, 70%, 40% and 0%) |
| Top | |
| EMCPro | |
| EMCPro-1 | EMCPro System comprising: Pro-BASE Base unit including front panel keypad and display, single phase 16A AC/DC coupler/decoupler and NEMA (US) outlet, Pro-ESD Electrostatic Discharge Simulator in accordance with IEC 1000-4-2; to 8.8kV Air and 4.4kV Contact discharge, with 150pF/330 Ohm discharge network (includes TPA-2 Air and TPC-3 Contact Discharge tips and carrying case), Pro-EFT Electrical Fast Burst transients simulator in accordance with IEC 1000-4-4; to 4.4kV, 100kHz, Pro-SURGE Combination wave surge simulator in accordance with IEC 1000-4-5; to 6.6kV, 3.3kA, Pro-RING 100kHz Ring wave surge simulator in accordance with ANSI C62.41; to 6.6kV, Pro-HPWR Power frequency magnetic field simulator in accordance with IEC 1000-4-8; to 4A/m (N.B. Requires CM-HCoil), Pro-HPULSE Pulsed magnetic field simulator; to 1000A/m and Pro-PQF Dips and Interrupts simulator in accordance with IEC 1000-4-11; to 110%, 100%, 70%, 40% and 0%. |
| EMCPro-2 | EMCPro System comprising: Pro-BASE Base unit including front panel keypad and display, single phase 16A AC/DC coupler/decoupler and NEMA (US) outlet, Pro-EFT Electrical Fast Burst transients simulator in accordance with IEC 1000-4-4; to 4.4kV, 100kHz, Pro-SURGE Combination wave surge simulator in accordance with IEC 1000-4-5; to 6.6kV, 3.3kA, Pro-TELECOM 10/700ms Telecom wave surge simulator in accordance with IEC 1000-4-5; to 6.6kV and Pro-PQF Dips and Interrupts simulator in accordance with IEC 1000-4-11; to 110%, 100%, 70%, 40% and 0%. Also available with Pro-RING in place of Pro-TELECOM |
| Accessories for CEMaster and EMCPro | |
| ECM.IOCD | External 8-line Coupler/Decoupler for I/O Signal lines with auxiliary clamping protection. |
| ECM.3CD | Semi-automatic 16A, 3 Phase EFT and Surge AC/DC Mains Coupler/Decoupler. |
| ECM.COIL | Magnetic field coil; 1m x 1m |
| ECM.3PQF | Semi-automatic 16A, 3 Phase Dip/Interrupt phase selector for testing a single phase of a 3 Phase system. |
| ECM.TELCD | External 2 or 4 line Coupler/Decoupler for Telecom lines to 100kHz with auxiliary clamping protection. |
| Top | |
| Expert Computer Aided Testing (ECAT) Systems | |
| Multi-function systems under manual or software control can be configured by specifying individual modules to suit your specific requirements. Please contact us should you require assistance specifying a system. |
|
| Control Center | |
| E103 | ECAT Controller with front panel and software control via Optical RS232 interface. |
| Series 400 Electrical Fast Transients/Burst Modules | |
| E411 | ECAT Electrical Fast Transient/Burst Module to IEC 1000-4-4. Output programmable to 4.4kV, burst frequency is adjustable between 1kHz and 1MHz up to 4.4kV. |
| E412 | ECAT Electrical Fast Transient/Burst Module to IEC 1000-4-4. Output programmable to 4.4kV, burst frequency is adjustable between 1kHz and 1MHz up to 4.4kV. Incorporates a single phase Coupler/Decoupler, 250V AC/DC, 16A. |
| E421 | ECAT Electrical Fast Transient/Burst Module to IEC 1000-4-4. Output programmable to 8kV, burst frequency is adjustable between 1kHz and 1MHz up to 4.4kV and between 1kHz and 250kHz to 8kV. |
| E424 | ECAT Electrical Fast Transient/Burst Module to IEC 1000-4-4. Output programmable to 4.4kV, burst frequency is adjustable between 1kHz and 1MHz up to 4.4kV. Incorporates a three phase Coupler/Decoupler, 480V AC/DC, 32A. |
| CCL-4/s | Capacitive Coupling Clamp according to IEC 1000-4-4 for coupling EFT/B onto signal and data lines. |
| Series 500 Surge Transient Modules | |
| E501 | ECAT Combination Wave Surge Module to IEC 1000-4-5, ANSI/IEEE C62.41, UL 14449 and Bellcore standards; 1.2/50 microseconds, 8/20 microseconds to 6.6kV, 3kA. |
| E502 | ECAT Telecom Waves Surge Module to IEC 61000-4-5, FCC Part 68 and CCITT Rec. K17, K20 and K21 standards; 10/700 microseconds and 0.5/700 microseconds to 6.6kV. |
| E503 | ECAT Ring Wave Surge Module to ANSI/IEEE C62.41 and various UL standards including UL 1449 and UL 864; 0.5 microseconds/100kHz to 6.6kV at 200A and 500A. |
| E504 | ECAT Combination Wave Surge Module to UL 1449; 1.2/50 microseconds, 8/20 microseconds to 6.6kV with selectable short-circuit currents of 125A, 500A or 750A. |
| E505 | ECAT Telecom Waves Surge Module to FCC Part 68; 10/160 microseconds to 1650V, 200A; 10/560 microseconds to 880V, 100A and 2/10 microseconds to 2.5kV, 1kA. |
| E506 | ECAT Surge Module with Bellcore waveforms for 2 or 3 terminal telecom port surges; 2/10 microseconds to 800V or 1500V at 100A and to 2500V or 5000V at 500A. |
| E508 | ECAT Surge Module to Bellcore GR-1089-CORE; 10/360 microseconds to 1.0kV at 100A for 2 or 3 terminal telecommunication port surges. |
| E509 | ECAT Telecom Wave Surge Module to Bellcore GR-1089-CORE; 10/1000 microseconds, 100A at 600V, 1.0kV and 1.5kV for 2 or 3 terminal telecommunication port surges. |
| E510 | ECAT Combination Wave Surge Module with extended range to IEC 1000-4-5, and ANSI/IEEE C62.41 standards; 1.2/50 microseconds, 8/20 microseconds to 10kV, 5.5kA. |
| Coupler/Decoupler Modules | |
| E551 | ECAT Surge Coupler/Decoupler; Single-phase, 250Vrms, 15/16A. |
| E4552 | Combined Electrical Fast Transient/Burst and Surge Coupler/Decoupler; single phase, 250Vrms, 15/16A for up to 8kV EFT/B and 7kV Surge waves. |
| E4552-DC | Combined Electrical Fast Transient/Burst and Surge Coupler/Decoupler; single phase, 250Vrms, 15/16A for up to 8kV EFT/B and 7kV Surge waves. With DC option to facilitate testing of DC power lines. |
| E4554 | ECAT Combined Surge and Electrical Fast Transient/Bursts Coupler/Decoupler; Three-phase, 480Vrms, 32A for Surges to 7kV and EFT/B to 8kV. |
| E455V-kV | ECAT Combined Surge and Electrical Fast Transient/Bursts Coupler/Decoupler; Three-phase, 480Vrms, 16A for Surge to 10kV. |
| Dips and Interruptions Module | |
| EP62 | ECAT Swell/Dip/Interrupt Module to IEC 61000-4-11; for single-phase AC lines to 240Vrms, 32A. |
| Pre-configured ECAT systems | |
| E1000-4-4 | Electrical Fast Transients/Burst system according to IEC 1000-4-4 comprising E103 and E412 (see above for module descriptions) |
| E1000-4-5 | Combination wave surge system according to IEC 1000-4-5 comprising E103, E501 and E551 (see above for module descriptions) |
| E801.91S | Electrical Fast Transients/Burst and Combination wave surge system according to IEC 1000-4-4 and IEC 1000-4-5 comprising E103, E412, E501 and E551 (see above for module descriptions) |
| Top | |
| Manual Test Systems | |
| 587-1 | IEEE 587 Manual surge generator; 6kV/3kA, with single phase 277V/16A Coupler and S1/S3 Ring Wave. |
| 801-5 | Manual combination wave surge generator according to IEC 1000-4-5; 6kV/3kA, with single phase 277V/16A Coupler. |
| S/S21 | Plug-in module for 587-PLUS to convert to an 801-PLUS; 6kV/3kA, with 10/700 microseconds Telecom Wave option. |
| S3B | Plug-in for 587-PLUS for increased current waveform; 6kV/5kA |
| 711A/J | IEEE 587 surge generator; 6kV/3kA with single phase 277V/10A Coupler and Voltage and Current monitoring options. |
| 711BK | IEEE 587 surge generator; 6kV/3kA with single phase 277V/30A Coupler. |
| 711P7 | ANSI C62.41 Category A and C surge generator; 6kV/10kA with single phase 277V/30A Coupler and digital Volt meter. |
| 711P9 | Bellcore 1089 surge generator (2/10 microseconds); 5kV/500kA with single phase Coupler and Voltage and Current monitoring options. |
| Top | |
| 424 Series Telecom Test Systems | |
| 241 | Classic (American) Telecom waveshapes; 1kV/microsecond voltage ramps, 10/1000 microsecond surge pulse; 1.5kV/60 or 15A with 424 mainframe. |
| 247 | Component test waveshape; 4/40 microseconds, 1.5kV/2kA with 424 mainframe. |
| 248 | FCC Telecom pulses; 10/160 and 10/560 microseconds, 1.5kV/200A(100A) with 424 mainframe. |
| 251 | Telecom voltage ramps; 1kV/microsecond, 500A with 424 mainframe, 210 and 211 plug-ins. |
| 281 | UL AC line ring-wave surge; 500ns, 100kHz, 6kV/200A with 424 mainframe. |
| 282 | FCC line surge waveform; 2/10 microsecond, 2.5kV/1kA with 424 mainframe. |
| 286 | Component test ramp generator; 100V/microsecond to 10kV/microsecond, 3.2kV/50A with 424 mainframe. |
| 293 | Telecom surge waveform; 10/360 microsecond, 1kV/1kA with 424 mainframe, 210 and 211 plug-ins. |
| 294 | Telecom surge waveform; 10/1000 microseconds, 1kV/100A with 424 mainframe, 210 and 211 plug-ins. |
| 295 | Telecom surge waveform; 10/2500 microseconds, 1kV/200A with 424 mainframe, 210 and 211 plug-ins. |
| FCC68 | FCC Part 68 packaged test system including 248 and 282 networks (see above for descriptions). |
| UL2 | UL waveforms packaged test system including 281 and 286 networks (see above for descriptions). |
| Top | |
Further information can be found on the TRANSIENT Specialists web site.